АА-2000 GTE TECHNICAL PARAMETERS
| № | Parameter name, unit of measurement | Parameter Value |
| 1 | Rated power of the GTE on the drive shaft under ISO conditions, kWt | 2100 |
| 2 | Output shaft speed, rpm | 25000 |
| 3 | Fuel consumption, kg/s | 0, 174 |
| 4 | Gas temperature at the exhaust nozzle outlet, К (° C) | 888 (615) |
| 5 | Air mass flow, kg/s | 9,5 |
| 6 | Fuel inlet pressure, MPa | 1,2 |
| 7 |
Weight of turbine, kg |
2500 |
| 8 | Overall dimensions (L х W х H), m | 2,7 х 1,5 х 1,6 |
АА-2000 GTE APPLICATION
|
|
|
|
FOR GENERATOR DRIVE (as part of the gas turbine power units - GTEA/GTES-2000 «Irtysh»)) |
| FOR CENTRIFUGAL COMPRESSOR DRIVE (as part of a gas pumping unit - GPU-2000 (2 MW) «Irtysh») |
|
FOR CENTRIFUGAL PUMP DRIVE (as part of the pump station for main oil pipelines) |
GTEA-2000 «IRTYSH»
PURPOSE
Power generation and power supply to the remote industrial and domestic consumers as well as for combined generation of power, hot water and steam (when GTEA-2000 is additionally provided with the waste heat boiler).
LAYOUT
The main components are: АА-2000 GTE and Generator located in the noise and heat insulated containers together with all necessary support systems (fuel, starting, oil, etc.) and auxiliary equipment. It is supplied in the form of modular units fully shop-assembled which can be transported by rail, road and by water. It is ready for operation after installation on the road or air field slab. The weight of GTEA-2000 “Irtysh” based on AA-2000 GTE is several times less than that of its equivalent based on the gas reciprocating engine.
Design: modular or shop – as required by the Customer
The test bench Gas turbine power unit - 2000 "Irtysh" powered by GTE AA-2000 at the factory site of INGC in Perm